Home > Buy Now > Relays > SF6 Ring Main Unit Switchgear
 


Ningbo Aux Hi-Tech Co.,Ltd
 
icon Products
icon Switchgear
icon Circuit Breaker
icon Load Switch
icon Fuse
icon CT & PT & Insulator Sensor
icon Substation

line

icon Company Profile

line

 
Contact us
Ningbo Aux Hi-Tech Co.,Ltd
[China]
Address:
No.1166 Mingguang North Road Ningbo Zhejiang 315191 China
Phone:
86-574-88072108
Contact name:
Peter , Sales Director
Inquire now










Ningbo Aux Hi-Tech Co.,Ltd



 
Switchgear

SF6 Ring Main Unit Switchgear

Inquire now

SF6 Ring Main Unit Switchgear

Click to enlarge image

 Model Number HXGT6(XGN58)-12

HXGT6(XCN58)-12 SF6 Ring Main Unit Switchgear (hereafter referred to as Switchgear) is designed and manufactured by ourselves according to the requirement of the power supply in our country.
As a new generation of Indoor 10kV electric appliances, by pattern test and commissioning, whose performance index is up to IEC298 [AC Metal-clad Switchgear] standard and relevant national standard. It is light in weight, easily operated, safe in usage, high reliability, independent of environment and free from maintenance etc.
The switchgear is a combined electric appliance that sealing each main circuit switch into a metal enclosure, use SF6 gas as arc extinguishing and insulation media, suitable for ring main power supply and double radiation power supply in 10kV middle voltage power supply network, use as terminal power supply as well.
The product is suitable for power distribution and control in mines, residential district, schools, parks ect, due to enhancing the reliability of power supply by ring main power supply.
In addition, with the character of easily wiring, small size, convenient installation, it is suitable for being installed in the Combination Substation as primary side HV equipment.

Product Feature :
a. Ring main unit is composed of three compartments. The load switch is laid in the sealed cubicle welded by stainless steel plate. There is SF6 gas of 0.04Mpa as the medium of extinction and insulation .
b. There are three positions, namely closing, isolating, earthing separately, whose positions are determined by the indicator on the mechanism panel.
c. The cable incoming/outgoing line uses cable connector (plug ins).
d. There is a separate operation mechanism in each compartment, where you can realize manual operation and manual and motor operation. There are closing/opening indication on the operation panel.
e. The fuse is installed in the epoxy resin tube in the middle of the cubicle. Due to the needle type mechanism of fuse and the opening device of operation mechanism in load switch are connected together, once the fuse is blew out with fault, the tripping mechanism will make the load switch opening.
f. The load switch apply revolving extinction arc principle, which will make contact long life endurance.
g. There is manometer in the front of the switchgear to monitor the pressure of the SF6 gas.
h. In order to prevent the inner of equipment from hyperbaria with circuit fault, there is a pressure release device at the bottom of the switchgear.